A quantitative comparison of four current portable ultrasound bladder scanners

  • D.R. Small

      Affiliations

    • Department of Urology, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 141 201 1528; fax: +44 141 201 2987.
  • ,
  • A. Watson

      Affiliations

    • Vascular Laboratory, Gartnavel General Hospital, Glasgow, UK
  • ,
  • A. McConnachie

      Affiliations

    • Robertson Centre for Biostatistics, University of Glasgow, Glasgow, UK

References 

  1. Stamm WE. Catheter-associated urinary tract infections: epidemiology, pathogenesis, and prevention. Am J Med. 1991;91(3s2):S65–S71
  2. Dudley NJ, Kirkland M, Lovett J, Watson AR. Clinical agreement between automated and calculated ultrasound measurements of bladder volume. BJR. 2003;76:832–834
  3. Huang Y-H, Bih L-I, Chen S-L, Tsai S-J, Teng C-H. The accuracy of ultrasonic estimation of bladder volume: a comparison of portable and stationary equipment. Arch Phys Med Rehabil. 2004;85:138–141
  4. Byun S-S, Kim HH, Paick J-S, Kamg W, Oh S-J. Accuracy of bladder volume determinations by ultrasonography: are they accurate over the entire bladder volume range?. Urology. 2003;64:656–660
  5. Pallis LM, Wilson M. Ultrasound assessment of bladder volume: is it valid after delivery?. Aust N Z J Obstet Gynaecol. 2003;43:453–456
  6. Barrington JW, Arunkalaivanan AS, Abdel Fattah M. The accuracy of Bladderscan in intrapartum care. Int Urogynaecol J Pelvic Floor Dysfunc. 2003;14:214–224
  7. Padmore DE, Anderson PA, Tooth DS, Wayne MA. Evaluation of a non-invasive method to determine bladder volume in children. Can J Urol. 1997;4:305–308
  8. Alnaif B, Drutz HP. The accuracy of portable abdominal ultrasound equipment in measuring postvoid residual volume. Int Urogynaecol J. 1999;10:215–218
  9. Ding YY, Sahadevan S, Pang WS, Choo PW. Clinical utility of a portable ultrasound scanner in the measurement of residual urine volume. Sing Med J. 1996;37:365–368
  10. Fuse H, Yokoyama T, Muraishi Y, Katayama T. Measurement of residual urine volume using a portable ultrasound instrument. Int Urol Nephrol. 1996;28:633–637
  11. Brouwer TA, Eindhoven BG, Epema AH, Henning RH. Validation of an ultrasound scanner for determining urinary volumes in surgical patients and volunteers. J Clin Minit Comput. 1999;15:379–385
  12. Coombes GM, Millard RJ. The accuracy of portable ultrasound scanning in the measurement of residual urine volume. J Urol. 1994;152:2083–2085
  13. Heverhagen JT, Hartleib T, Boehm D, Klose K-J, Wagner H-J. Magnetic resonance cystometry: accurate assessment of bladder volume with magnetic resonance imaging. Urology. 2002;60:309–314

PII: S1875-9742(08)00014-1

doi: 10.1016/j.bjmsu.2008.05.013

British Journal of Medical & Surgical Urology
Volume 1, Issue 1 , Pages 35-40 , July 2008